leaking water onto floor
replaced the poorly designed "duck bill" drain with this P trap. Very simple repair done by accessing through the back of the refrigerator. The video on this website walked me right through the repair. It did however fail to mention that the ice has to be removed from the inside. I had to remove the drawer face and pull outs. Then the ice maker and back panel are removed. I used a heat gun and screwdriver to chip and melt the ice build up. If one had the luxury of having another refrigerator to move food in to you could just unplug the unit until the ice melts.
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Bulb wouldn't light up, when freezer drawer was pulled open
The repair didn't get done, because both times that I requested a 25-Watt Light Bulb, I received a 3.6 Watt bulb instead & neither one worked. So I tried testing the original bulb in a table lamp & it worked. So I sense that the problem may be in the switch that allows the light to turn on when the drawer is opened & shut off when the drawer is closed.
Took too panel down. Remove.bulbs . Unplugged refrigerator. Removed electronic control board .installed new electronic control board. Plugged in refrigerator , programmed control for ice in about 1 hour refrigerator went to work and got cold Simple operation. Donald Harrell, Don's Repair Service .
Control noisy when opening and closing removed damper housing
Pop off vent cover remove 2 screws removed cover housing and foam. Removed damper by unclipping tabs on left and right side of control lift up and out. Unplugged power wires reinstalled in reverse order.
Easy fix, it's right in the back of the fridge under a cover that just clips in, a piece of foam, and two screws. The hardest part is getting the clips free without breaking them. After replacement it's silent instead of making a grinding noise regularly.
Defrost cycle not kicking in. Refrigerator not cooling. Freezer working.
I replaced the control board first. The freezer back panel frosted up and the refrigerator warmed up again. Then I force (short option vs long) defrosted the refrigerator. However, a few days later the defrost issue came back again. Force defrost no longer worked, though likely due to a severe ice build up behind the freezer panel. I ordered the wire harness. I took off the freezer door (loosen four screws only), removed the tray rails, ice maker, thermostat housing and vent mounted on the freezer panel. The rails and the vent are a bit tricky to remove since no directions exist. I then removed the fan above the coils and then removed the wire harness. Installing the new harness is easy except that I had to modify one of the ground connections for it to mount properly. I tested the unit for 72 hours. The defrost cycle eventually kicked in (dripping onto a pan and sizzling sound). I then reinstalled all parts. No frost build up. Good to go!
Took a putty knife and Removed the old switch removed the spade terminals from the old switch and replaced them on the new switch and just pushed the new switch back in place
Watched video. Unplugged refrigerator and popped out switch. In plugged connector and pushed switch in place. Plugged in refrigerator and the light worked
Refrigerator would cool for a very short period of time. Then the compressor would shutdown via internal thermal overload or high head pressure. This was caused by the lack of airflow across the condenser coils and compressor.
(1) Slide out appliance and remove power source. (2) Removed lower access cover on rear of refrigerator. (3) Disconnected plug to the condenser fan motor. (4) remove blades by pulling gently forward (5) remove mounting hardware holding the fan motor (3 screws) (6) motor is now free and new motor can be installed