Fridge and Freezer getting too warm.
In Freezer, removed the 3 screws hold up the dial to select the temperature. Once this is lowered you see the Cold Control Thermostat. New one was a bit different, but still fit. I carefully bent the sensor wire to come around to the front of the so it would fit. Slide the plastic tube over the sensor wire. I guessed on the Red and Yellow wires. I don't know if it matters if this is AC. I think I had the Red closest to the front. 2 prongs for the ground, but just need the small one. Put is all back together and it is working great.
Parts Used:
Cold Control Thermostat
  • Ted from NEDERLAND, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bad module on icemaker
First shut off water supply and unplug power. Unscrew icemaker assembly from side wall with 3 screws. Remove front cap and you can clearly see module. Unscrew and remove module ( only three screws). Install new module and revers procedure to finish up. Ice was ready in just a few hours. Video provided by this site was right on and left no questions.
Parts Used:
Icemaker Control Assembly
  • Randy from LAFAYETTE, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrig began to trip the GFI circuit in the garage. When plugged into a house interior circuit the lights and fan ran but no cooling in either the freezer or frig.
First of all I want to thank Michael from Carlisle,PA and this site for publishing Michael's info on the wiring specifics on the new 3 connector Start Relay ( WP2262185 ). The original relay only has 2 connectors The 2 orange wires which are combined to one female connector need to be clipped and separated each to its own connector. Refer to Michael's blog as to which wire goes to which connector on the Start Relay. I replaced the Run Capacitor, Start Relay and Overload just to be safe. The Start Relay was the actual culprit.Thank you for an excellent website!
Parts Used:
Run Capacitor
  • riley from CAVE CREEK, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Socket set
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker would not turn off. Kept making ice! Even turned off all water to house, but then realized that ice maker was being fed by pressurized RO tank!!
Broken plastic part in motor assembly. Very simple to replace. Sears wanted $322.00!!!
Parts Used:
Icemaker Control Assembly
  • Keith from Green Valley, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator stopped running
I was told to order the run capacitor and the technician thought it would repair the refrigerator; but it did not. The appliance technician had to take the run capacitor off and install what he called a "hard start" and the refrigerator is operating right now.
Parts Used:
Run Capacitor
  • Barbara H. from South Hill, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Circuit Breaker tripped/shut down frig. every 8 hrs when time switched on
Removed timer kit (this was the second time for this part)/ replaced - this is a fairly simple job and take 5 minutes. The defrost thermostat take about 10 minutes to get to and take out the old one, replacement is a 2 minute job, unplug and replace, the longest part of this job is getting the back of the freezer off and then replaced, but it is fairly simple to do. Total time to diagnose about 15 minutes, replacement parts arrived in 2 business days, replacement time 15 - 18 minutes total. Recommend getting the thermostat and timer together. The first time this happened, only order the timer but I think the problem was the thermostat all along and the time seemed to be operating but when it came on every eight hours it tripped the circuit breaker Not sure which was really the problem, but all working fine now.
Parts Used:
Defrost Timer Kit - 120V 60Hz Bimetal Defrost Thermostat
  • David from Atlantic Beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker stopped working
After checking the water valves ordered new ice maker. received the part three days after ordering! Clearing out food, removing the old one and installing the new unit took under 15 minutes. Everything went fine.
Parts Used:
Replacement Ice Maker
  • Raymond from Panama City Beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old Ice Maker failed
I removed the old ice maker and during the short disassembly noticed a burned out connection to the heater element that allows the ice to be broken free of the tray and dumped into the bin. Part Select had a new unit to me next day! I had watched their short install video, and read some of the user comments, already. Re-installing the new unit was a snap, and just as the video had described except for the mount bracket. The only thing that concerned me was that the new unit did not immediately do anything. I began to investigate and found that the flexible water "chute" connection had ice in it! I unplugged the refer, unscrewed the water filter and drained it. I disconnected the water feed on the outside back of the unit as well to make sure water could flow easily to the ice maker port. I filled the water filter with boiling hot water and replaced it, I plugged in the refer, and reprogrammed the date and time. Several hours later I checked the ice maker and it was -- making ice!
Parts Used:
Replacement Ice Maker
  • John from Gurnee, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker stopped functioning
Part received was what I needed. There was one issue--the 'feed' opening to receive water and direct it into the ice tray was a side feed and what I needed was a back feed. That means I had to do some exchanging of parts to make it work. That exercise took more time that the actual installation.
Parts Used:
Replacement Ice Maker
  • richard from colorado springs, CO
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers, Socket set
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker was over filling and causing water to flow into ice dispenser and freezing it al together
First turned off the water and unplugged the refrigerator and then removed the old ice maker by first removing the side cover plate and then next removed the ice level detector. Remove the screws that hold the ice maker in place and rotating it somewhat soas to gain access to the wires and then unplugged them. Next I had to modify the way the water comes into the new icemaker by adapting a CPVC street ell to fit into the hole on the side and then hook up the water supply. Installation is just the reverse of removal.
Parts Used:
Replacement Ice Maker
  • Michael from Moore, OK
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Abnormally warm temperatures in freezer/fresh food section
After unplugging the appliance I needed to thaw a large ice buildup off the evaporator cover panel before I could even remove the panel. The freezer being on the lower part of the appliance has the evaporator mounted vertically and it was 100% encapsulated in rock hard ice. It took over an hour to thaw the ice and collect all the water with a shop vacuum, since the condensate pan began to overflow.
One thawed, I checked all wiring for good connection, checked heater, defrost thermostat, timer unit with multimeter. The defrost thermostat checked out fine after putting it into another freezer for a 15 minute cooldown, but I noticed a crack in the seal and suspected internal moisture and decided to replace that part. A simple plug in of two leads to the new part after clipping it to the evaporator, replacement of the panel, and the appliance was up and running problem free.
A workbench disection of the old part confirmed my assessment, it had internal rust and water and had failed causing the defrost cycle failure.
Parts Used:
Bimetal Defrost Thermostat
  • James from Westfield, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator quit cooling and the freezer wasn't freezing anything
Order the part from the Internet on Sunday, it mailed out on Monday and I received it on Tuesday. I unplugged the fan then undone 3 screws that held the fan bracket to the refrigerator pulled it out unscrewed 3 more nuts and replaced the fan on the bracket and I cut the old wire plug off the old fan and with 2 wire nuts put it on my new fan. Replaced the fan and bracket back on the refrigerator plugged it in and it works like a new refrigerator.
Parts Used:
Condenser Fan Motor Kit
  • Tonya from Grand Prairie, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
leaky ice maker - non-stick coating had failed
replaced the entire ice make - 3 screws and a squeeze -off connector and it's out. Reverse to re-install... except that the fill tube had iced up. To thaw the fill tube: unload freezer section (leave food in fridge, but keep door closed), remove ice maker. Boil water, dip drill bit (dull end) into hot water, swirl around, insert (dull end) into to fill tube. Depending on how hot you got it, maybe a tablespoon of ice will melt. Repeat many times - fill tube is about 14" long! Do not use anything sharp - you will nick the tube and ice will form causing you to repeat this procedure. Do not try to break the ice - let the heat work. It took me about 30 minutes to thaw the whole thing - it made a nive gasping noise when the final plug opened up. Re-install ice maker.
Parts Used:
Screw Replacement Ice Maker
  • Robert from Sunnyvale, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
defective light switch
inserted a knife between the switch and the plastic interior in order to pop the switch out.
then took off the 2 wires on the old switch put them on the new switch and reinserted the switch into the plastic interior.
Parts Used:
Refrigerator Door Switch
  • THOMAS from WILLARD, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice cubes in bin frozen into big lumps due to water leaking into bin from icemaker. Lining of icemaker cube tray worn and damaged allowing leak.
Pull refrigerator out from wall to shut off water and power. Remove ice bin, pulling front down then out. Remove screw at bottom of icemaker, then pull down to release two clips, Pull out a couple inches to get hand behind icemaker to release wiring harness connector. (squeeze top and bottom to release clips). Remove unit. Remove wiring harness and wire bail from old unit and install on new unit. Reverse steps to install new unit. Make sure ice bin is fully inserted, or unit will not function.
Parts Used:
Replacement Ice Maker
  • Ross from Sun Lakes, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 59667275790