All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
Easy removal. Easy Plug and play install. Didn't even have to use the other wires. After install, put 4 oz of water into ice maker and wait....it didn't start making ice right away, but a couple hours later I heard the wonderful "ice dropping into the bin" sound. Worked great ever since.
1.removed 3 nut screws-2 on top &1 on bottom. 2.unplug ref. from outlet. 3.unplug the wires from ice maker to ref. 4.remove ice maker 5.rinse new ice maker 6.plug ice maker to ref. using included wires 7.screw 2 top nut screws first then the bottom. 8.plug ref. back to outlet 9.made first ice in about 2-3 hours
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Watched video. Unplugged refrigerator and popped out switch. In plugged connector and pushed switch in place. Plugged in refrigerator and the light worked
Refrigerator would cool for a very short period of time. Then the compressor would shutdown via internal thermal overload or high head pressure. This was caused by the lack of airflow across the condenser coils and compressor.
(1) Slide out appliance and remove power source. (2) Removed lower access cover on rear of refrigerator. (3) Disconnected plug to the condenser fan motor. (4) remove blades by pulling gently forward (5) remove mounting hardware holding the fan motor (3 screws) (6) motor is now free and new motor can be installed
water was leaking under the frig ,wasnt sure what the problem
decided to take a chance and replace the ice maker,so far no water leaking.feels nice to know the problem is fixed.thanks for the video on how to replace it, thanks again very easy repair
Control noisy when opening and closing removed damper housing
Pop off vent cover remove 2 screws removed cover housing and foam. Removed damper by unclipping tabs on left and right side of control lift up and out. Unplugged power wires reinstalled in reverse order.
Easy fix, it's right in the back of the fridge under a cover that just clips in, a piece of foam, and two screws. The hardest part is getting the clips free without breaking them. After replacement it's silent instead of making a grinding noise regularly.
Ordered new fan motor Got part took fridge apart Result was the motor was running The fan blade had come off the motor Replaced the motor anyway and reinstalled the fan, working well
Not much to describe. Just used philips screwdriver and removed the two screws holding the handle in place. Discarded the broken handle, washed the area where the original handle was and replaced it with a brand new white handle (not yellowed with age)by replacing the two screws.