Enter the code USA15 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on July 1 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
Unplug Remove entire back panel (both chipboard and metal fan grill) Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black) Unplug both fan wire connects from circuit block to release the fan power cable. Remove the fan mounting plate Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades Unscrew motor from brackets - note alignment of motor on brackets Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire) Connect new plug wire to the circuit block keeping wires connected to the proper terminals Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser Plug wire harness into motor and re-mount fan mount plate Reattach fan blade and secure using blade mount kit Replace back panels
I removed the screws and pulled the unit out a few inches. The wiring harness was difficult to disconnect since I did not know how it was being held in place. Once I did get it disconnected I saw there was a tab that had to be depressed. There was an access hole for depressing the tab but I did not see it until I had the unit removed. The instructions only say disconnect the harness, but not how. So I learned the hard way, damaging the harness.
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
I pulled the refrigerator out, and turned off the water valve at the wall. I then removed 3 screws at the bottom of the back panel so I could access the water inlet value. I compared the new part with the part on my refrigerator to make sure they were the same. They were.
Using a pair of adjustable pliers, and placing a small pan under it to catch the water in the line, I loosened and removed the water line.
I then removed the wires connected to the water inlet valve, noting how they were connected. I then removed the 2 screws holding the water inlet valve in place, and removed the old inlet valve.
I put the new inlet valve in place, and making sure to hook up the ground wire, replaced the 2 screws to hold the inlet valve in place. I reconnected the wires, and then the water line.
I turned the water supply on at the wall and checked for leaks. I then tried the water dispenser and it now worked perfectly. I tried it a few more times and then checked again for water leaks.
Replaced the 3 screw holding the back cover on, and pushed the refrigerator back into place.
R & R Icemaker Assembly. Took out 3 screws and unpluged Icemaker & replaced with new part. very easy and the service from PartSelect was fantastic. Very Satisfied, Ron Martin
Overall, replacing the ice maker wasn't too bad but it wasn't nearly as easy for me as it seems to have been for some. In my case, the fridge was an Amana and the ice maker was mounted in such a way that disconnecting the power connector was difficult. The ice maker had to be completely dismounted before any access to the power connector was even possible. The short power cables made it very difficult to get the ice maker into a position where I had a good view of the power connector enabling me to see how to release it. The only other challenge was the cup that the water line goes into. The replacement ice maker did not come with the right cup - the instructions said to replace the provided one with the old one. No instructions for this procedure were provided and it looked to me like it might involve significant disassembly, something I wanted to avoid for fear of breaking a plastic part on the new ice maker (something I had already done when disassembling the old ice maker). So instead of replacing the cup, I modified the new one to match the old one. This involved removing a cutout on one side and covering a hole on the other. Installation of the new ice maker went fine and the water leak problem was fixed.
No cooling, compressor not running and was very hot
Plied off the relay switch with a screw driver. I could not pull it off by hand. Disconnected the wires to it and replaced with new part. Had problem getting the part back on and lining up the pins with the connector. I had to line up one pin and start at an angle and roll the part onto the contact pins. I was impressed with the one day delivery without paying because it was shipped from a warehouse in California where the repair was made.
Icecubes came out half-way, and refrooze. I figured out, that the melter does not work (HEATER in the icemaker) Voltage measured 105V no load. Studied the Internet, and folloved an advice: shorted the back wire and the blackwire with white stripes.these go to relay contacts. It seems, that the relay contacts are no good on Infrared receiver boaed. I turn off manually the icemaker, when needed
Unscrewed back of fridge and unplugged relay from compressor and plugged in the new one remember that the new one turns 180 degrees from existing switch.
Once I got the right part the repair was quick and easy. All I had to do is get the old part off with a screwdriver and curved needle nose pliers and the old part came right off. The new part went in just as easy. Quick and easy. Less than 15 minutes.
My ice maker stopped working and just leaked water endlessly
First I ordered the ice maker, but not the wiring harness...didn't fix the problem so I ordered a wiring harness, but ordered the wrong one...so I emailed parts select and got a prompt response on how to return the mistake and which part I actually needed. It was a "special order" but got in within days. Wonderful service!
Removed back access cover with quarter inch nut driver, unplugged wire harness, pulled old relay out & plugged in new one, reconnected wire harness, and reinstalled access cover. Piece of cake. (Shipping was very quick) ***Frig was only 3yr an 1 mounth old.*** Maytag - Dependable Huh?
I removed the front cover--just popped off with no trouble. Removed 2 screws at the bottom. Slid the broken part out and put the new one in place. Put in the two screws, replaced the fron cover AND Done!!! BTW I am a 65 year old woman and the icemaker is like new.
Removed Ice bucket. Removed two screws and removed front cover from old ice bucket, two more screws under cover to remove ice agitator. Installed ice agitator to new ice bucket, installed two screws holding it. Installed ice bucket front cover on new ice bucket with two screws. Put new ice bucket into freezer. Finished! That was easy!