Very low flow from water dispenser, hollow ice cubes, broken ice dispenser helix
Unplugged refrigerator. Removed cardboard cover, vacuumed lint from coils and equipment area. Removed dual valves and labeled the four electrical leads with masking tape. Cut off the end of water lines to dispenser and ice maker to remove threaded connections (New are simply push on). The water leads are of different diameters, so there is no confusion.
Decided to replace water line at the same time so bought a plastic replacement for less than $10, removed old copper line and replaced it with new. (Original plumber used a custom made line with a smaller diameter and this may have contributed to the low flow).
Connected all lines and wires (had to use adapter supplied with valve for two of the leads which are of different connector widths than original) and secured valve and back panel. Had to bedn the valve mounting plate somewhat to allow it to fit (this is also a little different from the original).
After installation, it takes a little time to refill the lines until proper flow is established both at the dispenser and the icemaker.
Replacing the Helix took completely disassembling the ice drawer, Take your tiime in doing this as there are many parts that fit in only one precise way. This helix replacement took about 20 minutes total.
Parts Used:
Dual Inlet Water Valve Ice Dispenser Rear Helix
  • Osvaldo from Miami, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice buildup. The Ice Machine was frosting over. Ice (due to frosting) would block the drop chute.
Unfortunately, the replacement part didn't come with instructions. The repair, nevertheless, was fairly straightforward. After removing the plastic parts that guide the ice through the door (by removing a few screws that attach the parts to the inside of the door), I was able to slip my hand into the ice maker dispenser and remove the old part. The part clips on. It is a tight fit through the funnel (from the outside of the freezer), however, and requires that the gasket first be "flipped" open wherein it unfolds 180 degrees. Doing this will make it easier to clip the new gasket onto the assembly.
Parts Used:
Dispenser Door Assembly or Flapper
  • Tim from The Woodlands, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Solenoid controlling the valve had stopped operating.
I first tested to make sure the solenoid was receiving power. Every time the arm on the ice maker cycled, the meter would go up to 120v for about 10-15 seconds, and then back to almost 0, so I knew the electical control and timer was working as it should.

The valve was easy to change - took about 20 minutes total (including pulling the fridge out and pushing it back in). I just turned the water off, removed the valve assembly from the fridge, and took all of the lines off of the old one. I then hooked up the supply line to the new valve assembly. The lines to the water and ice had compression fittings on them, but the new vavle has a "push-in" connector. So, I cut the old water and ice lines squarely, just past the fitting, then pushed them in firmly. Plugged the connectors in, re-attached the vavle assembly to the fridge, turned the water back on, and viola - I had ice in about an hour! Gravy! :)
Parts Used:
Dual Inlet Water Valve
  • Eric from Rose Hill, KS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Top of refrigerator and freezer are warmer than bottom. Also, a large amoutnt of ice build up in the back of the freezer.
**Before you order a new part make sure you get the FULL model number off of the back of the refrigerator**
To even get to the back panel I had to melt the ice in the back of the freezer with a hair dryer. Once the ice was gone I removed 5 screws that held the panel that covers the coils. I melted more ice from the coils. I disconnected the connector for the old heater wiring harness and pooped the thermosat off. Then, removed the screws that held the heaters (2 per heater). Installed new heaters and connected wiring harness. Snapped new thermosat on. Replaced coil cover and plugged it back in.
Parts Used:
Defrost Heater with Thermostat
  • Andrew from Decatur, AL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer not frezing properly frost buildup
Removed housing around timer. Unpluged and
replaced timer. Defrosted freezer witk small portable heater. Freezer has worked greater since.
Saved a lot on service call.
Parts Used:
Defrost Timer
  • Bill from Columbiana, AL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
would not defrost
First I removed the light cover, one screw. Then I removed the rear coil cover, three Phillips screws and two hex head screws. I then defrosted the coils and removed the old defrost element and wiring harness, two hex head screws held in the element, wiring harness just unplugs. I the installed the new defrost coils ( new one had two coils but had a previously designed area for the second element ) and ran the wiring harness up to where the plug was. I then reinstalled the coil cover plate, and light guard and started the refridgerator. Frige runs like new. Thank you PartSelect for the extremely propmt delivery and the correct part. part
Parts Used:
Defrost Heater with Thermostat
  • Richard from Quakertown, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer coil iceing up
removed freezer racks and back panel. removed and relaced defrosting harness. reassembled compartment
PartSelect rocks! easy to locate needed parts. price is fair and quick shipping. saved me $$$$
Parts Used:
Defrost Heater with Thermostat
  • Paul from Palmdale, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken gear
Removed old gear and tapped the replacement on.
Parts Used:
Icemaker Motor Gear
  • D.H. from Mulberry, AL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Unit wouldn't maintain a low temp.
Opened back,found fan not moving. Cleaned out dust and dirt. Received exact fan motor. Easiest fix I ever performed(very unusual). Fridge now runs great! Also, water line to in-door ice and water dry roughted and sprung leak. Replaced tubing.
Parts Used:
Condenser Fan Motor Kit
  • David from Erie, PA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set, Wrench set
8 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
compressor not starting
Refrigerator is not cooling. Light and fan working. Changed the capacitor.. Still not cooling. Back to discovery mode.It may be the timer
Certainly not PartSelect's fault. They have great service.
Parts Used:
Capacitor
  • H.K. from Seagoville, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
9 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
knob broke off about 3 years ago, ice/water stopped working about 8 months ago
I only took on this repair on because of the comments I read here...was soooo simple!
Removed the knobs by pulling down firmly, popped off the front panel, removed 4 faceplate screws, popped that off...removed two screws holding the control board faceplate on. Unplugged the old control board, replaced it with the new one, plugged the new one in...replaced all the screws, replaced the knobs and it was done!!! One funny note...be sure to turn the electricity off to your fridge...when you reinstall the board water and/or ice start working right away. I think I'll go have a massage with all the money we saved by not having the repair person come out!
Parts Used:
Dispenser Control Board - 2 Slide Switches Recess Knob - Black
  • Laurie from Hermosa Beach, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
8 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator compartment warm, Freezer cold
This is a old 2000 side by side Kenmore frig bought from sears. left Freezer side was building up ice in the back, while right side was not cool at all. The Defrost Timer was behind the light panel on top in compartment side. Easily remove unit and unscrew things. Works like a champ.
Parts Used:
Defrost Timer
  • Hop from Houston, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator would begin to lose it's cool and we saw ice caking on the bacjk panel of the freezer section.
We had to empty the freezing section, remove the 4 screws that held the back panel and defrost the coils. Then with the diagram we got from the internet, we removed the defroster and easily installed the new one and put the back panel back on. We did find later that it was still icing over so I ordered the thermostat and we installed it today.
It too was easy to install. We spliced the wires and hooked the new thermostat to the old wires and reinstalled the back panel. Hopefully this will solve the problem for us now.
Parts Used:
Defrost Thermostat
  • Charles from Edison, GA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken fan blade in the freezer compartment
Unplugged frige, removed top shelf, pulled broken fan blade off. Replaced with fan blade just purchased from PartSelect. Very simple repair. Orderd and recieved the right part.
Parts Used:
Evaporator Fan Blade Kit
  • John from Cumberland, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
rusty ice maker
removed old parts and installed new. went smooth
Parts Used:
Auger and Front Helix Kit
  • Dean from Park Ridge, NJ
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!