Enter the code USA15 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on July 1 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
The water was leaking from below the refrigerator, and a big puddle was being formed.
First I removed the screws, and the covering at the bottom rear of the GE Fridge. I then removed the existing water valve which was the source of water leak, it was all corroded with the leak at the valve joints, so I knew the water valve needed to be replaced. The water valve I received from PartSelect fitted in perfectly, once I had removed the old valve. All I needed was couple of screw drivers for the replacement. I would like to thank PartSelect for making this easy and saving me lots of money & time by not going for outside professional help.
The comments from customers experiences gave me the confidence that the defrost timer was the problem since the compressor was still working and it went just as they all said, four 1/4' hex head screws and I had access to the old timer, unplugged the old ,plugged in the new and put the four screws back in. Nothing happened so after a while I looked a bit harder at the accessable part of the timer after intallation and saw what looked like a dial. I turned the dialclockwise and immediatly the compressor turned on. I have not found any information as to how much or little to turn this dial which obviously is an adjustable cycle setting so I just turned it all the way, so far everything is working alright.
Condensor Fan not turning. I thought it would be an easy fix. I thought I could pull off the shroud and fan assy - no joy. Too many copper pipes and lots of tubing in the way. It took 90 minutes to remove and 30 minutes to install. The BIG hint here is to loosen the shoud, pull it back as far as you can and then remove the nut that holds the fan blade in place. THEN you can remove the motor. Get the new motor back into the shroud, get the blade back on and then tighten the shroud back up.
1) Shut off water source. 2) Unplug Refrigerator. 3) Remove screws on bottom rear panel. 4) Disconnect water connection at valve assembly. 5) Remove single screw holding valve assembly. 6) Transfer electrical connections from old valve to new. 7) Transfer all water connections from old valve to new. Push in ring to release tubing. 8) Replace rear panel. Reconnect water source. Plug in refrigerator. Turn on water source.
Flapper not sealing. Frost buildup on inside of freezer door
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved
We couldn't get the other connector loose from one end of the tubing so he said just cut it and so we did and attached the connector. I now have water again in my fridge and took the sticky note down "don't use the water" as it had leaked for a year...... Thanks!
Plastic water line gets brittle from compersor heat over time and eventually brakes. I tried to fix with 5/16 line from a locel hardware store but outter diameter was slightly smaller so connection to valve leaked. This OEM part fit perfect. I cut the line beyond the brake and connected it with the tube union part, Easy fix. Everything works fine with no leaks
Unplug refrigerator,remove the freezer bulb, trays and rear cover to expose coils and heating element/defroster, The telltale sign its bad was it looked like an old flashbulb/burned, the old one was open, melt enough ice to remove and replace the defrost element(2 screws 2 wires) and reinstall components, reconnect power, thats it.
After replacing the solenoid several months ago, I concluded that the problem could only be the electronic circuit board that controls the timing and delay. The part arrived sooner than I expected. Installing it involved removing only six screws and unplugging two connections. The whole project took only about 10 minutes and now my ice maker works like new. Total cost was less than $55. Saved me several hundred dollars not to mention my personal time had I called in a repairman.
the left drawer slide rail was broken from years of use.
First I removed the vegetable drawer and glass shelf. I matched up the 'new' drawer slide rail next to the broken slide. I then used a phillips head screwdriver to remove the 2 screws that held the slide in place. After removing the broken slide rail, I installed the new rail, replaced the vegetable drawer and glass shelf. New item worked like a charm. The drawer slide arrived really quick after my order was placed. Approx. 2 days after ordering the part, it was on my front door step.
My husband did the repair, and even though our refrigerator is roughly 20+ years old, he was able to adapt it to work in all the right spots and we now have ice cubes! I'm very happy we did not have to spend $2000 on a comparable refrigerator.
Make sure you put everything back in the order you took them out.
I had to back-track acouple of times because I put the shelf brackets back in before I had the back panel in.It was also alittle tight getting the thermostat snapped back on the refrigerant line because it is a tight space and I have big hands.For a first timer who has had minimal experiance it wasn't too tough.
First I replaced the double valve because the ice maker was not filling with water. It still did not work. Then I replaced the ice maker itself. This worked and was relatively easy to replace. I had to use the water fill "slide" from the old ice maker. The new one was too narrow and it leaked water into the freezer.