freezer kept icing over, refrigerator too hot
First, I unplugged the appliance. Safety, first. Than I removed the shield which was held in by screws. This covered the fan, thermometer. The defrost thermostat was taken out, with a little extra force. The wires on the defective part were no longer attached to the part. The instructions were easy to follow in replacing the defrost thermostat. I stripped the coating on the wire, attached it with the enclosed electical bugs. The assy was able to follow, and the part went back on. The refrigerator is working perfectly. I couldn't have done it without the help in diagnosing the problem and with the speedy delivery of the new part. Thanks for all your help and the ease of the installing the new part!
took cover off inside freezer control . removed old fan and unpluged wire harness plugged new one up and fastened back in place and put control cover back on.
Removed the cowling with a square drive screw driver, removed the spring clip from the cover of the compressor controls with a screw driver, pulled off the old compressor start relay and replaced it with the new part. Since other problems could have caused the compressor to short cycle this was a "replace the part and hope it would work" since that would be the most common reason and it was not a very expensive part.
Make sure unplugged the frig before doing any repair. Just like other DIYers. opened up the evaporator located inside the freezer. Replaced the defrost thermostat, there's only 2 wires, so just make sure which is positive, which is negative. Replaced the defrost timer located on the bottom front of the frig. There's on 2 screws to unscrew. All those work took me less than half hour. Turn on the frig., now it works like a champ again. Hope it will last another 10 years.
The fridge motor was running constantly and the fridge was warm inside
I secured the power to the fridge. I took the metal panel which covers the cooling coils in the freezer off by removing the the 6 sheet metal screws. I used a standard hair dryer to melt the ice block which had formed due to the failure of the defrost timer. I replace the defrost timer, which was located behind the left front wheel of the unit. Finding the timer was the hardest part of the job. Since I was having trouble with the defrost cycle I also decided to replace the defrost thermostat due to its age. The most important item I would like to share is once all the work is done and the panel is back in the freezer, the power is restored take a straight slot screw driver and give the defrost timer about an eighth of a turn clockwise to ensure it starts. Then mark it with a sharpe and check it in 3 or 4 hours to make sure it is running. I did not do this on the one I installed and the freezer did not go into the defrost cycle. Once I got the timer started, well the ice cream stay frozen. BE SURE NOT TO WORK ON YOUR EQUIPMENT WITH IT PLUGGED INTO POWER SOURCE!!!
Drip pan had rusted & was leaking water on the floor
The BIG problem was getting the old drip pan off. The bolt on top of the compressor was too long to allow the removal of the old drip pan. I removed the old drip pan by cutting most of it away with tin shears then cutting the remaining part of the pan around the bolt with a hack saw (taking care not to damage freon lines and raising the pan above the threads of the bolt so as not to damage the threads). I still had to cut half the bolt away with a hack saw by replacing the nut and cutting a third of the bolt away (above the nut), so the new pan would fit. Putting the new pan on was a breeze after that. It may be easier to just cut the bolt off altogether on top of the compressor and use the wire clips per the instructions supplied with the kit to install the new one.
I replaced the solenoid first because the ice maker was not getting water. After replacing the solenoid valve, I waited about 1/2 an hour, still no water. So, I ordered a replacement ice maker. I then installed the replacement ice maker, waited a 1/2 an hour, still no water. Then, I waited overnight. Yeah, ice! WORD OF ADVICE. WAIT OVERNIGHT TO SEE IF THE ICE MAKER CREATES ICE. Not sure how long a cycle takes, but it's longer than you would think. Hope your installation is a success!
Freezer starter acumulating lots of ice and the lower part of fridge was not cooling at all.
just took the back cover of the freezer of and then the fan. To do this, I just removed like four bolts at the corners and then four bolts that attached the fan to the cover. At the end, I just unplugged the cables. I got my new fan the very next day, which was like extremly fast, plug in the cables and attached the fan to the cover and then attached the cover to the original place. It's a pretty simple repair. My fridge is now working like it should be.
Simple switch repair: Unplug fridge, pull down to remove switch assembly, slip contacts off. Reverse with replacement switch. HOWEVER, check first to see if the bulb filament might be broken, as this could cause the same symptom. OR in my case, the light socket connection was the culprit. Check that too before ordering a replacement switch.
Watched YouTube video. Very easy. Used my cell phone camera in ‘selfie’ mode propped up in the upper right hand corner of freezer to see the 2 hidden screws.
I put the refrigerator and saw that the fan wasn't working so I change the fan and the problem still the same. I order a timer and thermostat and change them, nothing change so I order the capacitor and when I remove it I saw that the relay swith was burn out so I order a switch and evarything is ok. The problem when the fan broke the compressor overheat and burn the swich. I learn a lot and still saving money over these repair guy.
I basically followed the instructions offered when i searched for the ice maker. It was relatively easy to do, I undid the 2 screws holding the ice maker to the side of the freezer, the was the tricky part, holding a mirror so i could see the slots of the screws. loosened them, disconnected the electrical connection and reversed the process for the install. It took about 25 minutes and i was back making ice.
Did the obvious. Removed the stick-out cover, then the back of the freezer wall, after taking the bad evaporator fan out. Replaced the old motor with the new one, stuck the fan blades back on, and put the replacement back in place. Checked to see that the new motor and fan, before final hook up, had no issues. That was a success. However, when I put the parts in place, I had some significant vibrations. By taking things apart and re-doing the install, the vibrations went away. However, the final install, even if quiet, did not work. Apparently the condenser was kaput. No cooling after all the adjustments. We gave up and are replacing the fridge.
I removed the plastic cowl in the rear of the freezer to gain access to the fan, took out two screws that secured the brackets holding the fan. Then I separated the coupling wires which had a sort of locking mechanism that was simple to undue. I took out the brackets along with the fan, separated the brackets and removed the screw for the ground wire. Then I simply reversed the process.
I opened the fridge door and lifted up the old gasket to investigate the situation. I saw that the inside door panel (the one that has the butter compartment and additional shelves for condiments) had screws every few inches. I determined that this was holding the smaller lip of the gasket in. I got out my trusty cordless drill and went to work. After a few mild cuss words, I did manage to get the very last corner on, as that is the trickiest part of the installation. Note that I am an almost "60" year old woman who has many other tools, including a chain saw, which I utilize every now and then. So if I can do it myself, I certainly will! The best thing of it all was that I ordered the part on 8/22/08 and when I arrived home the evening of 8/24/08, the box with the part was sitting on the back deck. Thank you partselect for a great product and great service.