Repaired Oven Range Light Bulb
The bulb has a plastic clear cover. That cover can just be carefully removed using a screwdriver. It's held in by a metal bracket. After you remove the cover. You'll just need to replace the bulb and then re-install the cover and bracket.
I had a broken fan blade due to ice build up from a leaking ice maker.
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker. 2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,. 3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket. 4.Now take out 8 screws that hold the back panel in place and remove the back panel. 5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
unplug power from ref removed old light socket only difference wired a little different checked new socket compaired to old checked terminal ends small big looked at wires big,little plugged up put in new light blub plugged ref power back on work power off pushed socket bac in power on works
From most posts I've read, the defrost timer was the culprit so I blindly ordered one. Easy install but did not fix the problem so I broke out the ohm meter. The only other 2 items it could be all tested good with my meter so I bypassed the defrost thermostat (per forum help...actually quite easy)and it defrosted fine, which told me I needed a new defrost thermostat. Installed fairly easy and problem gone.
Based on the website I decided it was most probably the defrost timer, and that was correct. I ordered it, watched the video, and two days later the part was at my door. Took the nut driver, removed 4 screws, then removed the old defrost timer, installed the new one, re-installed the whole plastic assembly with the four screws, and done!!! Couldn't have been easier.
For years we opened the refridgerator door and the things fell off the bottom shelf.
We ordered end pieces for the shelf holder, attached them to the long piece and snaped them into the door. Three minutes to open the box, attach, and close the door. A less than 20 dollar repair and success!
Refrigerator was not cooling and the motor was running constantly
Having tried PartSelect.com before, I was very comfortable with the process. Input my symptoms and the feed back I received was that one of the 2 things (Defrost Timer or Defrost Thermostat)might need replacement. Since the cost was not much and over night shipping would cost more than the product, I decided to order both the parts. Changing parts was a breeze. The instructions posted by others on your web site were very easy to follow. You guys save me a bundle every time I have any thing going worng with any of my appliances.
Temperature in both freezer and fridge sections to warm!
Dear Part-select, I had a fridge that was not working food was melting in the freezer, Beer was warm. You get the picture anyway using your site I found the parts needed to to fix the issue in fact I ordered two parts one fixed the issue 50% and the other like 30% of the time! both parts with overnight shipping were cheaper than 1 part if purchased at our local appliance part outlet:) not to mention the cost of a repair person. Thanks again! . Keep up the good work
Tom Houck Spokane, WA Houck Photo 509-723-3418 tomhouck1@comcast.net
I replaced the shelf end caps in the shelves of my fridge and I also replaced the gasket around the door.
Every time I would open the door, things would fall out because the shelves were giving, because the end caps were broken. Once I got the new ones, I was amazed that these parts are still available and that they lock right in with no problem. Once you get one in, you then have to place one end of that retaining bar into that, very tightly, making sure the end is completely secure in the cap. Then you can lock the other cap to the other end, lock it into place in the door and whala! It is just that simple.
Now the gaket is another story, it is best to soak the gasket in hot water first to draw it up abit so it will be snug and also to use lubricant such as petroleum around the inside where it is going to fit to the door. This made it extremely easy to afix to my door with no problems. I am so glad for this site.. hundreds of dollars saved!!
I removed the compressor start relay and replaced it with the new part. Initially it did not work. When I checked my work, I had to tighten the connector on the new part. Once I made the correction, the freezer is freezing normally again.