Enter the code USA15 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on July 1 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Lightning struct the house and fried the evap thermostat
Noticed the evap fan wasn't working, so trying to disconnect the wire broke the connection so had to order a new motor. Installed the motor but it still didn't work. Had a technician look at it and he said it was the control board. Ordered and installed control board and still didn't work. The only element left is the evap thermostat. Jumped the thermostat and it worked so ordered and installed a thermostat. It works now
I called in because the model # of the refrigerator did not show up on the website. The cust. srvc. rep looked it up and found the part. It was reasonably priced, I received it in a matter of days and it fit perfectly. Thank you! We were preparing to put the condo on the market and broke the shelf while cleaning. It was great to have a resource for a reasonably priced replacement and quick shipment.
Evaporator fan motor quit and would not circulate cold air from coils.
Remove shelves and rear panels to get to motor. Motor is held in place on shroud by simple strap. Remove fan blade, then un hook strap, remove and save rubber spacers on old motor to reuse to remount new motor. New motor Mew motor has wiring harness that is universal. Cut out the three wires that go to the new motor leaving long as possible, cut wires from old motor as long as possible, strip ends of all wires 1/2 inch, connect wires by color,slip into provided wire connectors and crimp. Pull on wires to insure connection. Tie wires together so they don't touch the coils. Plug in and check operation. If all is working unplug and replace all covers and shelves. Plug back in and it will take few hours to reach operating temperature. Video of side by side repair shows easy removal of panels and motor.
I unplugged the fridge and unscrewed the back cover,unscrewwd the two screws holding the water valve in place and the water line to the ice maker and the electrical connection and install the new water valve,then buttoned everything back up and plugged the fridge back in and it is working great,making ice as normal.
removed ice maker,,and screws holding back of freezer cover,unplugged wires and removed the cover and fan.wow,only wire to element had come unplugged!went ahead and replaced thermostat,and defrost timer,both were easy to do
Pull refrigerator from wall and disconnect the water line and unplug the power.
On top of the icemaker, two machine screws hold the icemaker to the side of the refrigerator. You will have to feel around to find the machine screws, but once you do, it is simple to slip the appropriate size socket over the hex heads. I found it helpful to have an extension on the socket wrench. Disconnect the power cable inside the refrigerator (there are little pressure clips on the side that help release the cable) and move it out of the way for the time-being.
Back out both machine screws several turns, but do not remove them completely. The icemaker slips over the screws, so leaving them in the side of the refrigerator makes that process a lot easier. Hand tighten the machine screws once you have positioned the new icemaker in place. One thing to be sure and do is make sure the water line hose coming out of the back of the refrigerator inside is on top of the icemaker. It fits into a slot in the top of the icemaker - failing to do this will result in water pouring into the freezer compartment, not into the icemaker..
Reconnect the power cable to the new icemaker and tuck it up behind the icemaker assembly. Tighten the machine screws completely, but do not over-tighten.
Reconnect the water line on the back of the refrigerator at the wall, and plug in the refrigerator. You should hear the unit fill immediately.
In about an hour you should have ice filling the bin. Enjoy!
Pulled the refrigerator out from the wall. Then unplugged it took my nutdriver with a1/4" socket on it and took out the screws from the cardboard back on the bottom of the refrigerator. Then I removed the two screws holding the water valve on. Then I unscrewed the supply water line from the main water inlet valve. Then I removed the outlet waterline going to the ice maker from the water valve. Then I reversed the procedure to put it back together. Hooked up the main water line and turned the water valve on for the water to flow to the valve at first nothing happened had to wait for a couple of hours for everything else to get to the right temperature before the ice maker would start making ice.
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the wiring harness plug, replaced the old timer with the new one, re-connected the wiring harness and reinstalled the mount in position. Hardest thing about it was lying on the floor.
I broke the glass shelf in my refrigerator. I had trouble navigating the website, so I called the customer service line, and the lady was lovely to speak with, and ordered my part quickly! In 2 days I had the part, and it fit perfectly!
The refrigerator crisper pan cover cracked in the front center.
I removed the glass from the cover, removed the 2 crispier pans and removed and discarded the broken cover. I installed the new cover by making sure the back was flush against the back wall of the refrigerator. After that I replaced the glass and drawers and it was as good as new.
Turn off ice maker Slide wire harness shield off connector Disconnected harness Loosened 2 wall screws Remove old ice maker Installed new one reversing process