Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
support rail had broken lower slide
Could have done it with my eyes closed! Removed shelf and drawer, then removed broken support rail. Removed screw from broken rail and put the new, two piece rail together using that screw. Snapped rail back onto wall...returned shelf to fridge...returned drawer to fridge...returned myself to sanity! Yee Haw Easier than installing it was ORDERING IT. I was amazed by the ease of that process. Your ordering site is incredibly easy. By the way...I am a blonde and for blondes everywhere...Look at what I could do :)
Lightning struct the house and fried the evap thermostat
Noticed the evap fan wasn't working, so trying to disconnect the wire broke the connection so had to order a new motor. Installed the motor but it still didn't work. Had a technician look at it and he said it was the control board. Ordered and installed control board and still didn't work. The only element left is the evap thermostat. Jumped the thermostat and it worked so ordered and installed a thermostat. It works now
Evaporator fan motor quit and would not circulate cold air from coils.
Remove shelves and rear panels to get to motor. Motor is held in place on shroud by simple strap. Remove fan blade, then un hook strap, remove and save rubber spacers on old motor to reuse to remount new motor. New motor Mew motor has wiring harness that is universal. Cut out the three wires that go to the new motor leaving long as possible, cut wires from old motor as long as possible, strip ends of all wires 1/2 inch, connect wires by color,slip into provided wire connectors and crimp. Pull on wires to insure connection. Tie wires together so they don't touch the coils. Plug in and check operation. If all is working unplug and replace all covers and shelves. Plug back in and it will take few hours to reach operating temperature. Video of side by side repair shows easy removal of panels and motor.
The repair was a simple replacement. The problem was that after waiting three weeks for the new drawer to arrive I had to call the company and ask what the delay was?? They said the first order was lost in the mail?? Second order arrived within a week. But we didn't enjoy having to wait this long.
Pull refrigerator from wall and disconnect the water line and unplug the power.
On top of the icemaker, two machine screws hold the icemaker to the side of the refrigerator. You will have to feel around to find the machine screws, but once you do, it is simple to slip the appropriate size socket over the hex heads. I found it helpful to have an extension on the socket wrench. Disconnect the power cable inside the refrigerator (there are little pressure clips on the side that help release the cable) and move it out of the way for the time-being.
Back out both machine screws several turns, but do not remove them completely. The icemaker slips over the screws, so leaving them in the side of the refrigerator makes that process a lot easier. Hand tighten the machine screws once you have positioned the new icemaker in place. One thing to be sure and do is make sure the water line hose coming out of the back of the refrigerator inside is on top of the icemaker. It fits into a slot in the top of the icemaker - failing to do this will result in water pouring into the freezer compartment, not into the icemaker..
Reconnect the power cable to the new icemaker and tuck it up behind the icemaker assembly. Tighten the machine screws completely, but do not over-tighten.
Reconnect the water line on the back of the refrigerator at the wall, and plug in the refrigerator. You should hear the unit fill immediately.
In about an hour you should have ice filling the bin. Enjoy!
removed ice maker,,and screws holding back of freezer cover,unplugged wires and removed the cover and fan.wow,only wire to element had come unplugged!went ahead and replaced thermostat,and defrost timer,both were easy to do
very nioce rental unit, people slammed door w/Crisprers open
No big deal. Placed the order, got the replacement. Put them in and that was that! The great thing is, I have a perfect refrigerator for new renters. It would have been a lost rent without these easy to get parts. Thank you.
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the wiring harness plug, replaced the old timer with the new one, re-connected the wiring harness and reinstalled the mount in position. Hardest thing about it was lying on the floor.
Icemaker worked sporadically, infrequently, not at all
Not knowing the history of the refrigerator/freezer and observing that the icemaker would cycle (ice ejector fingers would rotate when the off/on arm was toggled), I concluded that the water valve must have some hard water scale in it which was causing it to stick. I replaced the water valve and the exact same behavior continued. By elimination, I concluded that the microswitch in the icemaker must be sticking. I removed the icemaker, used a hair blow-dryer to heat/dry out the microswitches and then a little shot of WD-40 on the mechanical arms, switches, and cams fixed it.