First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires. Then I took the new icemaker out of the box and reversed the procedure.
Removed 4 screws holding face plate onto ice bucket. Removed the 3 screws holding the ice crusher housing. Noted postion and rotation of teh s;ring loaded ice selecting rod. Removed broken crusher housing. Reveresed process for installion. Took for test drive. Operational...
Brand new refrigerator, but evaporator fan blade broken, causing considerable vibration and noise.
Really, really, really easy: 1.Unplug refrigerator (electrical safety). 2.Remove cardboard cover at bottom of refrigerator (two short self-tapping bolts) with a wrench. 3.Pull old fan blade off fan motor shaft (just held on by a compression fitting--no tools needed). 4.Push new fan blade on shaft. 5. Replace cardboard cover. 6. Plug in refrigerator, write nasty letter to Frigidaire.
The old ice maker had stopped working properly. The cycle was inconsistent, and inlet water would run over existing cubes in the tray, before they were dumped into the dispenser box.
This was really simple, much like changing a light bulb. Two bolts loosened beneath the old unit to allow it to be lifted off and free. The power supply plug was easily disconnected. The new unit was then placed onto the loosened bolts, power supply reconnected and secured with the supplied wire tie. A small angled bracket was removed from the old and reattached to the new as a support toward the from of the unit. The cycle adjuster was backed off a 1/2 turn as per the instructions....and the next morning....new automatic ice. Life is good!
pulled old gasket out of groove in door. Put vaseline on slotted part of gasket that fits in groove of refri. door Put some vaseline on gasket surface that would be on the hinge side of door, so it would close with ease. Had no problems at all. Thanks
P.S. Sorry about not having the model No. The Part No was PS1991324 Magnetic Gasket for Refr side of a Freezer/Refrigerator FRIGIDAIRE There are no screws to remove on this model. Just start at one corner and begin pulling old gasket out of the groove of the door.
The repair was easy. The problem was the lack of explanation. This may help other customers. I was told by the virtual trouble shooting system that about 30% of the cure was to replace the water filter and 70% was to replace the water valve. I did both and still had the problem. People need to be told why they have to replace the water valve. The reason is this. The valve has a very small leak in it that lets water continue to flow into the freezer compartment drop by drop. Eventually, this freezes and clogs the hole , so no water can pass and thus no ice can be made.In either your web site or another they stated that it may freeze up here, but there was no connection to the water valve.It seemed like it was another topic. Its very hard to see the frozen area, unless you remove it from the freezer area. I wish I was TOLD TO DO THIS, after i replaced the valve It would have saved me a repair bill. I hope this helps others. Take care-Bill
The in the door ice dispencer would not dispense ice since the auger wasn't working properly to push the ice through the door.
Pulled the old ice container assembly out and discarded it and inserted the new one. It immediately worked and now dispenses both crushed and cubed ice through the door.
Installed 3 new door shelves, took less in then 10 minutes. Yes, all 3 broke at once. The original shelves were cheap. The new ones from Parts Select feel a lot more durable.
The radiator was not being properly defrosted and the refrigerator and freezer could not keep the temperature. Two things can be causing this, the defrost module which defrost the refrigerator on a regular basis ($110) or the thermostat ($18). I tried the thermostat since it is very easy to do (remove cover plate inside the freezer, cut wires of old thermostat, connect new thermostat by stripping wires. Presto...however the thermostat was NOT the problem. The problem was a blown timer circuit board that controls the regular defrosting. That repair was done by a technician. The board was $110, it seats inside the refrigerator in the control panel area.
This process was so easy. I put in the model # and saw the piece I needed immediately along with a picture of it that helped me confirm it was the right one. All I had to do is snap the shelf in when it arrived.
I had already removed the ice maker by loosening the two screws with a 1/4" nut driver, in order to compare the design and style to the intended replacement for size and critical measurements. The replacement was almost identical. The wiring harness was 2-3" longer than the original, but after snaping the wire plugs together I simply curved the wire up and to the left to be out of the way. The hanging brackets are slotted and it was easiest to slip the back hanger over the head of the screw and let it slip down, then the front hanger was already to line up even though you can't see the screw with the ice maker in the way. I had to transfer an L-shaped metal bracket to the bottom side, matching the old assembly, and adjusting it to hold the bottom side away from the freezer compartment a little so it would hang level and secure. You have to snug the two screws with a screw driver or 1/4" nut driver by feel, since you can't see them with the icemaker in place. It took about 10 minutes to take out the old and another 10 to put in the new. We now have a full bin of ice, and the old plastic trays have been retired. I should have done this a year ago.
Housing that the water filter was cracked. I think ,setting was too cold and froze and cracked it.
It takes a 1/4 " nutdriver to take one screw out that holds the cover over the water filter. You have to come up from the botton of cover. Then take two water lines off housing , by pushing the round collar back toward the fitting,and pull fitting off housing. Then take the two screw out that hold the housing on. Make sure you have the water turned off before you start.
Unplug turn water off Removed two screws with nut driver loosen one Disconnected three solenoid valves Disconnected four water lines Plug tubing in, tighten one flare fitting Reattach wires to solenoids Slide under loose screw, replace two screws Turn water on check for leaks plug in get a drink of water