evaporator coil would freeze up solid. no air flow through coil; no cooling.
-unplug power cord.(safety first! -Removed evaporator cover in freezer. found defrost thermostat defective. -use hair dryer to manually defrost coil from ice build-up. -unclip thermostat from coil. -cut wires close to the defrost thermostat; remove defective thermostat. -clip on new defrost thermostat. -connect wires using included butt connectors including shrink tubing (also included) -replace coil cover. -plug power cord back in.
Removed the two screws that hold the element in place. Then I pulled the element out about 3 inches and disconnected the wires. Everything matched up perfectly.
take out screws front control panel ,then screws on left panel holding control unit. had to clean up plastic she got a little toasty. unhooked control unit replaced with new and reassembled. The real story is in your excellent web site easy to find exactly what I need and with prompt shipping, I was back in service quicker than having someone come out and repair.
I removed the old gate by using a flat head screw driver to pry open mouth. I then removed 2 bolts that held on the cage that hols the ice crushing blades. Then I inserted the new gate and used a screw driver to pry the mouth open again (it was more difficult to insert than remove). I then popped in the new gate and re-assembled the cage. It worked on the first shot with no problems!
This is the 3rd time I have attemped and successfully repaired major home appliances myself after the warrenty ran out. I'm sure I could buy a new appliance for the money I saved.
un plug fridge. removed ice maker from fridge. loosen 2 mounting screws. lift unit in slots to get over heads of screws. unplug wire harness. remove cover. remove 3 screws from control housing. remove 2 motor mounting screws. unplug motor wires from switches w/needle nose. installation is the reverse. plug in fridge turn on icemaker. takes 10 to 15 min to start to cycle. easy and cheaper than new fridge or ice maker
I shut the water off under the sink and removed the back piece on the refrigerator, unscrewed the water valve, cut the ends off each plastic hose and reinserted into the new water valve. Then rescrewed the water line into the new water valve and turned on the water. Unfortunately, I was not able to get water out of the door and the ice maker still doesn't make ice. While this was an easy procedure, it didn't help me. I'm not sure I needed to replace the water valve.
This was a simple job. Raised the flap in the back that houses the compressor, removed the wire that holds the relay, pulled out the old relay and pushed the new one on. Replaced wire holder and that was it. Plugged it frig and freezer is at zero and lower compartment at 35. As easy as brushing your teeth!
I located the part that was the culprit as it had buzzed very much before quitting. This is an easy removal as the part is in a two prong jack and just needs to be carefully removed with the new part inserted back in the jack provided. The refrigerator works fine now, but the run capacitor will still buzz on start up of the compressor. I do hope this is normal in this model? anyway it runs fine mow. Thank you.
Filter housing was cracked & water was leaking all over the refrigerator
First I turned off the water supply to the frig and raised the bar in the ice make to stop the production of ice. I used the nut driver to remove 3 screws from the housing. I removed the connections from the two water lines & removed the broken housing. I attached the water lines to the new housing and then screwed it back into the refrigerator. I replaced the filter and screwed the filter cup into the housing. Turned on water & ice maker, then ran water thru the door dispenser to check to see if I had done it correctly. No leaks !!! Yeah....I was done !!!
Fan motor no longer functioning and needed to be replaced
The most difficult part was the removal of the existing fan and shroud. There is very little room to work between the condenser and the coils where the fan is located. The old shroud had to be removed as it was not compatible with the mounting for the new fan motor and blade. Make sure to unplug the refrigerator and give the coils some time to cool down. The first step was to remove the old fan blade... it simply pulls off. Next you need to remove the two bolts holding the fan shroud to the floor of the refrigerator. Then you need to remove the old fan motor from the shroud... unplug the wire connection and remove two small bolts that hold it on. I was lucky to have a VERY small ratchet to get into these tight spaces. Now is the really hard part, removing the metal fan shroud takes a lot of twisting and turning to get it out. The coils have a little play in them, but you must be very careful of the tubing and connections. Also, the coils are very sharp. Once this is out, IF you can get it out....I had my doubts along the way, you can start to put the new parts in... beginning with the new fan shroud which fortunately is made of plastic and has some give which makes it easier to get in. Then you can mount the new motor to the shroud with the three new screws. Plug in the wire connection, add the foam tape to the shroud and mount the shroud to the floor of the frig with the original two bolts. Lastly, attach the fan blade. This replacement kit is well constructed, fits perfectly and contained all the necessary parts (fan motor with wiring connection, mounting screws, wire connection adapter, fan shroud, foam tape and fan blade), but no detailed instructions come with it. I was lucky to get the old fan shroud out without doing any damage to the surrounding parts, but this part was very difficult for a do it yourself person. I would be interested to know if a professional has some other tips for this part of the replacement process.