Ghislain
July 16, 2023
Is that parts fits my 2011 GE wall oven
wb24t10081
For model number pck916bm3bb
Hi Ghislain, thank you for your inquiry. Yes, the mentioned part is compatible with your model. We hope this information is useful!
1 person found this helpful.
Was this helpful?
Thank you for voting!
Randy
October 9, 2019
I tested the high limit switch at room temp - the continuity was 0, and the resistance was 00.3-00.5 at 200 oms, and 000 at 2000 oms. So i ordered a new one and it tested the same. Are both of this parts working properly, or should i be getting a reading from 1000-1100?
For model number WB24T10081
Hello Randy, thank you for your question. When testing the resistance of the Hi-Limit Switch, a reading of about 1080 ohms at room temperature is a good reading. What is occurring with your oven, and can you provide the model number for it? We can look further into this for you. We look forward to hearing back from you!
Was this helpful?
Thank you for voting!
Terry
October 11, 2019
My double oven won't heat and it clicks like it is trying to cycle or a relay is trying to work.
For model number PT956SR2SS
Hi Terry, thank you for your question. There are a few parts that could cause this issue in your appliance. First I would say test your elements with a multi meter to see if they are working correctly or not. They should be reading between 0 - 50 ohms to be working correctly. The other part you should check would be your oven temperature sensor. That can also be tested with a multi meter and should be reading between 1000 - 1100 ohms. If those three parts are fine however, then the issue may be in your control board. I hope that helps. Good luck with your repair.