Janis
January 21, 2018
This is not freezing, but seems to be defrosting. The door is not sealing hard when shutting the door. I checked the door seal which seems okay. I changed to another plug. The freezer is level. Can you help?
For model number UL4000ECW3
Hello Janis,
Thanks for your question. Your issue could be related to the compressor start relay. If you have a multimeter, test the relay for continuity and replace it if it shows no electrical continuity.
I hope this helps.
alot of frost build up on shelves, also food becomes frosted after only a short time, temp is set at 1
For model number mfu17m3bw3
Hello Chris, thank you for contacting us. The most probable cause of the issue is a faulty control thermostat, part number PS425344. We would recommend checking it with a multimeter. Also, check the door gasket, part number PS447455, and make sure no warm air is leaking into the freezer. Customer service is available 7 days a week if you need help placing an order. Glad to be of assistance!
CONDENSER SEEMS REALLY HOT AND DOESN'T SEEM TO BE OPERATING
For model number FFFU14M1QWJ
Hello Darin, thank you for reaching out. Based on our understanding of the issue, we would recommend checking the compressor start relay, part number PS11757754, to fix the issue. We hope this solves your problem!