Ice maker wouldn't change from crushed to cubed ice
First I pulled the ice tray out so I could see the solenoid housing/ice tray support(1 unit). Below the ice tray there are 2 screws that hold the solenoid housing/ice tray support. After removing those the assembly lifts up so you can see the wiring harness to disconnect. I pulled it out and removed the 2 screws to open it up. There is 2 screws holding the solenoid in place and one ground wire. This was an easy fix and I know I saved a lot of money.
Simple three steps... 1) There's an front section to the ice-maker to take off. One Phillips screw is on the side, one screw is underneath near the inside of the refrigerator wall. Just unscrew and store. 2) There's a small plastic unit just inside the ice maker to take out. It's held in by a small nut that requires about a 4" extension to reach. (You may be able to unscrew the nut with small needle-nose pliers). Just unscrew and take out the unit - the unit functions just to keep the ice maker wiring in place. 3) The wiring looks a mess, but there's just one wiring connector to the ice maker assembly. Unsnap it. The ice maker is not screwed in, it just slides in -- reach in and pull the assembly straight out; when it stops, lower it a bit and it will come free. Reverse the instructions to install the new unit.
My fridge temp was warm. Freezer temp was ok, but fluctuated some.
I checked the dampener, it worked. The compressor and fan worked. I knew because my freezer was still hovering around 10 degrees. Coils were clean. Thermistor was the only thing it could be. Took all my shelves out. Removed four screws. Took the back panel off. The thermistor sits tucked in on the side. I piped it out, in clipped it. Used my multimeter to test the numbers. Numbers were off just a bit. Ordered the part. Crossed my fingers.,took less then 5 minutes to put the part in. Plugged in the fridge. It was sitting at 33 degrees in about an hour and a half. I can’t believe I fixed it. I knew NOTHING about refrigerators. For how big my fridge is, it would have cost 3,000 and up to get a new one with the same cu ft size. Instead, it cost me $44. That includes shipping. Thank you Parts Select!! Made it so easy to pick the correct part for my model fridge!
Pulled the old gasket out if groove on the door, cleaned inside the groove, squirted some windex in the groove to ease the new gasket in the groove, then proceeded to work the gasket into the groove. Made sure gasket was all the way in the groove around the perimeter of the door. Done!
Roller screw recipients broke out. Can't be repaired.
Was not able to repair. Wasn't rollers I needed. Plastic screw recipients in front on frame had broken out so rollers weren't the problem. Tried gluing back pieces to no avail. Crisper frames are poorly designed.
took the cover off (cardbord) the fan will come off and go back on by hand no tools needed i changed the fan motor just to be sure. 3 little screws hold it on. the plug only goes on one way u can't mess it up.very easy job u shouldn't have any problems doing it.Jim
When removing existing filter you will experience some resistance at the 10-4 position which requires a little extra pressure to reach the 9-3 position.
Not making ice in both ice maker or dispensing water
To confirm my diagnosis I first replace the filter still no water flow. Check water supply from the wall valve: ok Remove the entire inlet valve assembly and sit it over a small bucket. Disconnect the tubing from the bottom of the 1st selenide valve: this is the one leading to the filter. Place cup under water dispenser and activate dispenser. No water discharge from inlet valve confirm valve is bad. Install the new valve matching the colored tubing with the color on each inlet valve. Re-connect the water supply place container under water dispenser and activate: There will be a large gush of air then water. Dispense aprox 1 gallon of water to confirm all the air is purged from the system. Your refrigerator is now back to dispensing water and making ice. Good luck everyone - Neville
REPLACED WITH NEW. HOWEVER, THE WATER FILTER INDICATOR STILL SAYS 'REPLACE'. THERE IS NO LEAKAGE, BUT IT APPEARS LIKE THE NEW CARTRIDGE IS NOT COMPLETELY INSERTED. I'VE TRIED REMOVING AND REPLACING THE NEW CARTRIDGE SEVERAL TIMES, BUT IT STILL SAYS 'REPLACE'. INCIDENTALLY, THIS WAS THE SECOND ORDER OF THE CARTRIDGE AND LAST TIME I GOT TWO, AND THEY BOTH FIT FINE! WITH THIS ORDER I GOT JUST ONE.
crisper Drawer and cover roller broke of the left rail
I was not able to repair it because I could not remove the drawer, I pulled it out to the stop as instructed but the cover came out as well. very difficult to repair.
Unscrew a few screws and remove some plastic covers to access the ice cube tray. Undue two wire connections and remove the tray. Put in the new unit in reverse order. I heard it may take awhile for the new ice maker to start doing anything. Mine didn't do anything for 6 hours, then made it's first batch. Making ice fine now ever since.
2 drawer undercounter beverage ref not getting cold enough. Wont get below 48°
Took drawers out by removing 2 screws on top of rail near front, then popped black plastic cover off in lower right inside cabinet...sensor just un plugged and new one plugged in easily...did not fix problem though...display set at 34 but bottom drawer reads about 40 at best and upper drawer reads around 55...dont think the 3 little fans inside on back wall have been running