Timer would run but the microwave won't start
I first removed the top plate above the microwave door (3 screws), then I removed the plate containing the buttons and clock. The microwave has 3 relay switches and they are in a little holder. The holder was too difficult to remove so I just removed the bottom switch and replaced. The microwave started right up.
was told buy a repair person to check the door micro switches as it was a common problem. removed the top plastic air grill to get access to the screw that holds in place the control cover. After unplugging the unit, i took out the (2) screws that held in the switches and removed them (3). One switch was a bit melted so i tested it with a 12 volt battery and it was bad. Ordered a new one from Part select and got it fast . Works great .
After unplugging the unit remove the control face buy removing the screws. All three door switchs are on a bracket on the left. Remove the two screws holding the bracket in place and pull out. Disconnect the wires from the three switches and test each switch indivually to determine the bad one. I used a multimeter set on ohms.Replace the bad switch with the new one and replace all the wires. Reassemble the unit and you are good to go.
It is a undercabinet stovetop microwave. First had to take it down and unplug. Remove the top cover locate the door switch. Used neednose pliers to remove switch. Unplug two terminals.Plug new switch and use pliers to replace back @ same position.Plug in socket temporarily to see if it works.Afterwards if it works.Unplug and replace cover.Ready to be replaced back under cabinet.
Replaced rectifier to no avail still have the same problem. Original rectifier tested bad and was replaced with the new one.. I checked door switches, magnatron, and capacitor all test good. I am stumped please give me some more troubleshooting ideas Thanks
This is an OTR microwave oven, needs to be removed to diagnose problem. I did not diagnose problem properly, I searched online for possible causes, read that (99%)percent of the time the interlock switch was bad and replacement should solve my problem. It was also stated to be an easy fix,15- 45 minutes depending on ability. I ordered the relay switch. Took the oven down then removed outer shell. With my multimeter I began to test, fuses(2), interlock switches(3)and transformer. 3 interlock switches were ok, fuses were fine, and had power to the transformer, meter could not read output of transformer because of high voltage, (2300v). I'm down to magnetron (about a hundred bucks) or the touch pad/ circuit board. I have a countertop micro that I'm putting in place of the OTR. As far as Partselect, my item was shipped and delivered on time, instructions for changing that part was quite accurate. Would order from here again, just do my homework first.
Removed unit from above stove removed outer housing, interior shield and tested the 4 door relays. One was not working. Replaced parts and re installed unit over stove.
the transformer started to smoke very badly while in use
I removed the cover and was able to see the burned up transformer. I removed the transformer and did a yahoo search for the part. I found you guys and ordered the part. the part arrived as advertised and I installed it. The microwave has been working now for 2 weeks. One word of advice make sure to use masking tape and mark the wire hookup locations. I used my Blackberry movie as well before I removed the old transformer. I was able to see the wire hookup locations when it was time to reinstall.
I purchased one relay switch (there are three) took one out one by one and replced it with the new one and tested it each time until it worked. Super easy and saved me hundreds of dollars by doing this myself.
Power, light, and clock work, micro/turntable not working
Much like the other post: 1. Removw vent case on top (3 screws) 2. Remove cover with control buttons (1 screw). 3. Removed bottom relay switch and replaced. Tight working space so be patient. Took 15 minutes Needle nose pliers used to crimp connector onto switch
Instructions did not match the assembly of the ice maker.
I managed to move the auger far enough to allow me to insert the cup-drive and then realign the auger with the new cup-drive. I also have had one to break very shortly after installing it. This is my second part to replace and this one went really smooth, since I understood that the initial parts installation instructions did not apply on my ice maker.