Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
bulb had broken off in base that was still screwed into socket
At first I tried to use pliers to unscrew the base,very uncomfortable working position,upside down and backwards(the microwave is installed over the range top)very limited space for your body and arms to manuver and you really cant see the base,all of this took place after the breaker was turned off ofcourse,finally figured out that you can drop the entire bottom housing of the microwave by unscrewing 6 screws and the light sockets are easily accessable once you lower it,take out 1 retaining screw ,remove the entire socket and unscrewed the broken base and replaced the bulbs,I said bulbs,there is no sense in having to replace another bulb in who knows how long since only one had burned out but they were both the same age
Clicking sound then within a minute clicking again, not cooling.
UNPLUG REFRIGERATOR. Carefully remove relay from the side of the compressor. You shouldn't need a tool to do this, if it is hard you can gently pry the edge with a flat head screw driver just to loosen. Unplug white and red wires from relay, noting that the white wire goes in the hole with a #2 stamped beside it. Shake old relay, if it rattles like a baby rattler then it's most likely the problem. Replace wires into the new relay and plug back into the compressor.
I removed all of the expandable pins that held the gasket and the inner door panel, and removed the old gasket from the inner door panel. The new gasket was then placed around the edges of the inner panel. While holding the gasket and panel in the proper location, the expandable pins were inserted into the mounting holes, finishing the installation.
Loosen screw holding glass cover plate in place over bulb. Glass cover plate will swing down. Unscrew bad bulb, replace with good bulb, reset glass cover and tighten screw.
I used a small screwdriver to disconnect wires from old starter. I connected the overload and starter, two wires. I put the unit back in the keeper, plugged the unit in, turned up the thermostat and it's working beautifully.
i looked byhind the freezer , the mottor has the relay connected to it.i took out the relay, and i descovery something was loose inside, i decided to take to check out at sears to see if they have in stock that especific relay. they did not have, they could order, that's when i dicided to go ahead and looking for in the internet, good i found PARTSELECT,they had the part and i was very nice attended,they sent in 2 days i had fix my freezer. thanks PARTSELECT. gilmar couto.
The replacement of the light no problem, the reason the light broke; problem. The original was glued in (for transport i think) and simply trying to unscrew it out (in a very tight slot) it broke; be careful or you’ll be buying a new $20 bulb (with shipping and handling).
Un screwed the cover but when i tried to remove the bulb it was broken at the base. I disconnected the power and used neddle nosed pliers to remove the base
The compressor wouldn't run it kept going on and off and wouldn't stay running,
I unwired the overload and installed the new overoad. Plugged the starter in to the back of the compressor and wired it up. Now I'm trying to get the freezer filled up again!
Used the flat edge of a screwdriver, which caused me to break off the corners of the plastic shield. Be nice if their was a tool to grab the anchors to pull them out
Defrosted freezer, hose broke due to dry-rot. Used towels to let water drain into pan. Now with the plug minimal frost build-up. No ice at all. Now if I could get a new hose to drain the water that would be great.
bulb burned out light that is under the microwave, which lights the oven below.
thank you for the video--very clear, responsible, applicable although the illustration was not exactly of our kind of light. the bulb was exactly like the one Hotpoint used in its microwave made in 1989! I will come back to you for parts in the future. (You have the model # from my original order.)