Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Lights inside refrigerator not working
I used a flat-head screwdriver to pop out the old light rocker switch. Then, I unplugged the wires, plugged them into the new light rocker switch, and then popped the new switch into the hole. That's it! Lights began working again.
An easy job for smaller hands. Removed the two bolts holding the light cover. Removed two electrical connections from the old switch by pinching the retaining clip,removed the switch, snapped in the new one and re-attached the connectors. Your online illustrations helped me to know that the plastic housing for the light switch would only swing down so far and was not intended to be removed. Saved me from breaking that plastic cover's tabs. This home repair saved me more than 5 times the cost of hiring a professional to do it. Very happy homeowner.
Had to replace a hose connector at the base of my refrig/frreezer
Perhaps a helpful hint:
When aI received the hose adapter/connector, I inserted the 2 hose ends only to have water drip from the connection. I used a utility knife to remove an inch from each side, then reinserted the hoses. That made the differnce. Dry as a bone.
The light switch on the refridgerator broke - no light.
Once I saw the replacement part I understood how to pry out the switch with a small screwdriver. Then just unplug the old one, plug in the new one and pop it into place.
The PartSelect site made it easy to correctly identify the correct part, it was inexpensive, and the shipping was fast.
Removing the old unit was difficult. The light was clearly designed for installation not for ease of repair. Since I was concerned about marring the surface of the refrigerator I used a paint scraper to get under the lip of the light and another smaller paint scraper to lift the unit away from the body of the refrigerator. It does not just "pop off". I eventually did get it free without any damage to the wall of the refrigerator. The repair was then very easy. There was a connector that was easy to separate allowing for the removal of the old unit without cutting any wires. The new unit had a mating connector, which easily connected to the old connector in the refrigerator. After some pushing I was able to install the new unit into the hole in the refrigerator. It does not exactly "snap in".
Refrigerator would ice up around the condenser and through out the air vents. Stopping all air flow in the refrigerator. If you defrosted the refrigerator it would work for about 24 hours then ice up again.
Unplugged and empty refrigerator, completely defrosted refrigerator using a hair dryer to speed up the defrosting, put a lot of towels on the floor to soak up the water when the ice melts. Removed all refrigerator racks and drawers, then remove the white plastic and styrofoam condenser cover. You will then see the thermistor, cut the two small wires connecting the thermistor to the harness leave yourself as mush wire as possible. Splice in the new thermistor and put the refrigerator back together.
tested bulb good ,replaced door switch first(least expensive)then ordered light socket and circuitboard.If clicking sound is heard replace circuitboard first to save on return shipping because the switch and socket where ok
researched on line and found the wiring was in series and I the suggestion was to replace the first light in the series that was in the freezer. Ordered the replacement light board and took out the existing light and pooped in the new one. Lights now all work! 15 minutes at tops.
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one. But Parts Select is a great place to order from. Thank you.
The refrigerator display said I need to replace the filter.
When the filter arrived, I removed it from the package. Upon reading the instructions, I removed the old filter. When I removed the old filter I NOTICED HOW IT CAME OUT SO THAT I COULD HOLD THE NEW FILTER IN THE SAME POSITION AND REPLACED IT WITH THE NEW IN THE SAME POSITION. When I closed the cover door, I went to the display panel and reset water filter display.
Received the union I ordered, then discovered that the tubes were different sizes, so I had the wrong part. I had read elsewhere that it was necessary to trim the two ends of the tubes with a box cutter to stop the leaks - I did this, and the leaking stopped. I was then able to go to a local hardware store and get a 5/16 to 1/4 union and replace it. The leaking is stopped, and the water supply in the door is now working like new. No problem with partselect, but I did buy a caliper so that I can check tube diameters if I ever have a similar problem! This is a great site to find instructions - well worth the time to search!
I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.