This 40w light bulb is a replacement bulb constructed of glass and metal. It is an easy-to-install electrical part which produces 40w of light. If the bulb won't light up then it may be broken and sho...
$8.89
In Stock
Order within the next 11 hrs and your part ships today!
This Charcoal Filter traps grease from your oven's exhaust to help prevent it from entering the vent, which could cause damage over time. If the exhaust fan on your microwave is not working, you may n...
$11.55
In Stock
Order within the next 11 hrs and your part ships today!
This Grease Filter is constructed of Acrylonitrile Butadiene Styrene and is used to trap grease and help eliminate odors from the exhaust air while cooking. It attaches onto the exhaust and is rated ...
$35.51
In Stock
Order within the next 11 hrs and your part ships today!
This mounting plate is sourced directly from the original manufacturer for use with microwaves. It is a metal plate designed to support a microwave by attaching the microwave to the wall studs. If the...
$15.87
In Stock
Order within the next 11 hrs and your part ships today!
This three-terminal switch fits your microwave door. This part is mostly black in color and is about 1.5 inches with metal terminals. You might need to replace this part if your microwave is not heati...
$10.37
In Stock
Order within the next 11 hrs and your part ships today!
This door interlock switch is for microwaves.
Door interlock switch prevents the microwave from starting when the door is open.
Because the microwave shielding and interlock switches must be pro...
$33.74
In Stock
Order within the next 11 hrs and your part ships today!
This diode, or high voltage diode, is used in microwaves. It is an electrical current control device that ensures power flows in one direction and not the other way. If your microwave produces no heat...
$29.58
In Stock
Order within the next 11 hrs and your part ships today!
The light socket in your microwave houses the light bulb and connects it to the power source. The light bulb will screw into it, so the light bulb will be held in place. Be very careful when installin...
$11.16
In Stock
Order within the next 11 hrs and your part ships today!
This damper is an authentic OEM replacement assembly used in microwave/range hood combos. It includes the damper door and frame. It is designed to direct the flow of air through the vent duct, and the...
$73.24
In Stock
Order within the next 11 hrs and your part ships today!
Questions And Answers for MMV5208WS1
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
9 questions answered by our experts.
Sort by:
< Prev
1
2
Next >
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Norm
February 7, 2020
Top shield on top of stainless steel microwave needs to be replaced
For model number MMV5208WS1
Good Day Norm. Thank you for your question in regards to your unit (Model Number MMV5208WS1). Based on our research the PartSelect Number for the part that is compatible with your unit is PS2361008. You can order this part either online at our website www.PartSelect.com or by calling us by phone at 888-260-4310. Best Regards.
Portable generator was connected to the main power panel of the house apparently the connection was wrong to the point that i presume 220 volts reach the 120 volts receptacles and since that time the micro wave dont turn on and theres no light in the display.I verify the fuses (2) for continuity and are ok.
what parts could be damage or need reemplace?
thanks
For model number MMV5208WS1
Hello Luis, thank you for your question. We would recommend testing the door switches first and if they are found to be ok, the issue is most likely the main control board Control, Electric Part #: PS11756441. I hope this helps!
3 people found this helpful.
Was this helpful?
Thank you for voting!
Victor
January 31, 2020
When I attempt to turn the microwave on, the interior light blinks and nothing happens. Everything else works normally, ie. fan, lights, etc. Have replaced all three door micro switches.
For model number MMV5208WS1
Hi Victor,
Thank you for your question. If you have replaced the door switches and the microwave will still not turn on, there are some other parts that you will need to check to see which one is causing the issue. You will also need to check the line fuse, the light socket, the interlock support, the interlock spring and the cam plate. We hope this helps. Thank you and have a great day.
1 person found this helpful.
Was this helpful?
Thank you for voting!
Ronald
November 26, 2022
It’s says call for service
Code F6
For model number MMV5208WS1
Hi Ronald, thank you for reaching out. According to our research on the error code, the Electronic Control Board appears to be faulty and you may need to replace it with part number PS11756441. If you need help placing an order, customer service is available 7 days a week. Glad to be of help!
Looking for the 30w 125v replacement bulb for the interior cooking compartment not the one underneath the microwave, but the one located on the top behind the vent. Do you know where to get one?
For model number MMV5208WS1
Hi Sue,
Thank you for your question. The part number listed under your model number for the light bulb that is found behind the vent is PS2376034. If you need help placing an order for it, customer service is open 7 days a week and anyone will be happy to assist you. Please feel free to give us a call. We look forward to hearing from you!
The nightmare was that this microwave is installed under the cabinet....in order to get to the light bulb I had to pull out my stove then squeeze into the space between the stove and counter....my old microwave light bult was much easier to change.....Shame on Whirlpool for making this so difficult.....must be a better way to cover the li
... Read moreght bulb so that we do not need a screwdriver to remove the door to get to the light bulb
Ordered top & bottom micro-switches and mounting plate parts. Internet reviews could not find specifics if the issue was due to a top/bottom or combination of micro-switch or mounting plate failure. Pulled the plug. Removed the top vent assembly cover held in by 2 Phillips screws inside the vent. Removed the control panel held in by 1 P
... Read morehillip screw at the top vent assembly area. Lifted control panel upward to release the catch and moved it off to the side - didn't disconnect any leads. Used a Torx bit to remove the door switch mounting plates at the front and pulled the plates through the opening from the control panel. Documented the wire color code connections, the top plate uses 2 micro's with one using both the closed & open contact. Installed the respective micros on the mounting plates and worked backwards with the wiring and removal steps. Once completed, the open/close sensing has worked every time.